Choose a firewood conveyor by the receiving point and the complete wood-yard layout, not by length alone. The right machine must accept suitable wood from the splitter or processor, reach the intended destination in an approved operating position, leave room for people and vehicles, and remain practical when the receiving pile grows. Maximum pile height is only one part of that decision.
A conveyor is most valuable when it removes a recurring handling stage. If split wood is repeatedly picked up from the ground and moved into a trailer, mechanizing that movement may help. If the main delay is cutting rounds or supplying the splitter, a conveyor may leave the bottleneck unchanged while adding setup, storage and maintenance.
This guide uses the Wallenstein CT16B and CT24B as documented examples, drawing on the January 2024 manual and Canadian product information checked in October 2026. The numerical examples explain a selection method. They are not operating-angle approvals or guaranteed production figures for an unknown conveyor.
Define the start and finish of the job
Before taking measurements, decide where the wood starts and where it should finish. “Move wood away from the splitter” is incomplete if the pieces must later be loaded again. A more useful definition is moving suitable finished pieces from the splitting station into the actual receiving pile, container or vehicle.
Keep that definition the same when comparing alternatives. A conveyor that leaves wood in a temporary pile has not completed the same job as one that loads the final destination. Conversely, a temporary pile may be intentional if drying, sorting or another process requires it. State that requirement rather than assuming every extra movement is waste.
The splitter power-source guide addresses the upstream machine and its scheduling demands. Conveyor selection begins after that: what movement remains once the piece is split, and which equipment or person currently performs it?
Five measurements that matter more than a catalogue headline
| Measurement | What to record | Why it matters |
|---|---|---|
| Inlet position | Height and location relative to the splitter or processor. | The conveyor must receive material without creating an awkward transfer. |
| Receiving height | The relevant vehicle side, container opening or planned pile condition. | A high discharge point is useful only if it clears and reaches the actual destination. |
| Horizontal placement | Distance from inlet to desired landing point. | Length used to gain height is not all available as horizontal reach. |
| Operating footprint | Machine, people, incoming wood and vehicle movements. | The equipment rectangle is smaller than the working area. |
| Stored envelope | Length, width and height in the approved lowered or folded condition. | A machine that works in the yard still needs practical storage and access. |
Measure the restrictive condition, not only the easiest one. An empty receiving vehicle may be simple to reach, while a nearly full load leaves less useful clearance. A gate may be wide enough on a straight approach but difficult when the tow vehicle must turn immediately before it.
Use a drawing with the vehicle and splitter in place. It does not need to be sophisticated. Mark the conveyor’s inlet, outlet, support points and the route used to replace a full vehicle. That drawing often reveals a conflict before a longer machine is ordered.
Length, rise and horizontal reach are connected
A conveyor’s working length lies along its inclined material path. Raising that path changes the relationship between vertical rise and horizontal reach. For an ideal straight line of length L at angle θ, rise equals L multiplied by sine θ, and horizontal run equals L multiplied by cosine θ.
As a geometry illustration only, a sixteen-foot line at thirty degrees has an eight-foot rise and about 13.9 feet of horizontal run. Those values do not predict the CT16B’s discharge height or approve a thirty-degree operating angle. A real conveyor has an inlet above ground, structural offsets, supports and manufacturer-defined operating limits.
The example explains why a sixteen-foot conveyor is not sixteen feet of reach at every height. It also explains why making the machine steeper may solve a clearance problem while moving the landing point closer to the inlet. The actual approved geometry must be checked on the machine.
Do not use a trigonometric calculation to override an angle indicator or operating restriction. Use it to understand the questions, then verify the proposed arrangement with the manufacturer’s dimensions and a suitable demonstration.
Maximum pile height is not a trailer-loading guarantee
A pile-height specification describes a manufacturer-defined capability. It is not automatically the clear space below every part of the discharge assembly, the allowable height of a trailer side or the height at which the entire load can be filled evenly.
The CT16B specification table lists an 8.5-foot maximum pile height, while its raised overall height is 119 inches. Those figures refer to different things. The Canadian introductory copy also uses eight feet five inches, which differs from 8.5 feet. Tight clearances deserve direct verification rather than rounding away the difference.
The discharge must do more than clear an edge. It must place the material where intended while keeping the receiving arrangement suitable as the load grows. Check the horizontal distance past the edge, the material’s path and the available room for repositioning.
For a ground pile, the limiting condition may be the growing slope of the pile rather than the initial discharge height. Plan where the next material will go when the first landing point is no longer useful. That can require a deliberate stop and reposition rather than a more aggressive operating angle.
A documented sixteen-foot versus twenty-four-foot comparison
The January 2024 Wallenstein manual lists the CT16B with a sixteen-foot trough and the CT24B with a twenty-four-foot trough. Their maximum pile-height figures are 8.5 and 13.5 feet respectively. The longer model also has a larger storage and positioning envelope.
In the lowered condition, the manual lists 212 by 70 by 63 inches for the CT16B and 307 by 74 by 83 inches for the CT24B. The longer machine therefore needs more than extra working reach; it needs additional space when parked and moved. Verify the specific serial-range documentation before applying these examples to a used machine.
Choose the longer arrangement when a measured receiving requirement or observed reduction in handling justifies it. Do not buy unused length simply to avoid taking measurements. For a nearby low receiving point, a shorter machine may leave a more convenient vehicle route and working area.
Also consider whether the larger machine changes the means of moving or storing it. An incremental purchase price can be a small part of the difference if a new storage arrangement or different transport method is required.
Feed geometry can be the real constraint
A conveyor must receive the output in a controlled, appropriate way. The inlet may be too far from the splitter, too high for the intended transfer or positioned where the operator needs to stand. Solving discharge height while ignoring the inlet can create a less practical station.
With a horizontal splitter such as the WX310, assess the path from the working bed to the conveyor. With a machine used in multiple orientations, such as the WX540, repeat the assessment for each intended arrangement. One conveyor position may not suit both workflows.
Do not use extra people near moving mechanisms as a substitute for a workable transfer. The labour plan must fit the equipment’s operator positions and exclusion zones. A useful demonstration shows how the actual team can feed material using the permitted routine.
For a processor feeding a conveyor, verify the intended interface rather than assuming two machines will align because both handle firewood. Height, material release, clearance and the rate of arrival all matter.
Material shape and arrival rate matter
Split wood is not a perfectly uniform product. Length, shape and the way pieces arrive can affect how they enter and travel along the conveyor. Use a representative sample when evaluating a machine rather than a hand-selected group of neat pieces.
A burst of output from a splitter or processor may differ from a steady hand-fed stream. The conveyor needs an appropriate receiving arrangement and monitoring. A higher chain speed is not a universal solution to overloaded or poorly placed material.
The CT manual instructs operators not to load too much wood at once. That is a useful reminder that a conveyor is a controlled material path, not an unlimited buffer. If the upstream machine regularly produces more than the receiving system can accommodate, assess the sequence and equipment match.
Record interventions during a demonstration. If material repeatedly needs clearing, stop and determine whether the issue is the setup, material suitability, adjustment or machine condition. Do not normalize repeated unsafe intervention as part of the expected workflow.
Repositioning is a planned part of the work
A growing pile or changing receiving vehicle can require angle or position changes. Those interruptions should appear in the productivity estimate. The machine’s positioning features do not necessarily permit movement while operating.
For the documented CT16B/CT24B configuration, the manual requires stopping the machine and removing the wood before changing the angle or position. It describes pivoting wheels for positioning, but those wheels are not permission to move a running, loaded conveyor.
Leave enough space to carry out the approved procedure without dismantling the whole work station. If every move requires relocating the splitter, towing vehicle and raw wood pile, the initial layout may be the problem.
When comparing two lengths, count how many planned movements each requires during the same complete batch. A longer conveyor that avoids one move may help, but its setup and storage costs still belong in the comparison.
Independent engine power and the rest of the equipment
An engine-powered conveyor can leave a tractor’s PTO or hydraulic supply available for another task. That independence may be useful when the tractor moves logs or receiving containers. It also adds an engine, fuel and service routine.
Confirm the actual power configuration rather than assuming all conveyors share it. For the CT examples, the January 2024 manual lists a Vanguard five-horsepower engine. The operator still needs the engine’s own documentation for maintenance and identification.
Do not infer runtime from fuel-tank size without consumption data under defined conditions. Likewise, engine horsepower does not establish the rate at which the whole wood yard produces finished loads. The machine may spend time waiting for pieces or for a receiving vehicle.
The same distinction between power architecture and material flow appears in the chipper feed-system comparison. For conveyor selection, keep the drive arrangement, material transfer and receiving geometry as separate questions before combining them into one operating plan.
Compare elapsed time and labour-hours separately
Suppose an existing process uses two people for ninety minutes to split, move and load a defined batch. That is three labour-hours. A proposed conveyor arrangement uses one person for two hours, including setup and cleanup. It takes longer on the clock but uses one fewer labour-hour.
Now consider a different arrangement that keeps both people working for seventy minutes. It finishes sooner but uses about 2.33 labour-hours. Neither outcome is universally better. The choice depends on whether the property values elapsed time, reduced labour demand, fewer repeated handling movements or some combination.
These are hypothetical comparisons, not conveyor production claims. To make them useful, hold the starting material and final destination constant. Include stops, vehicle changes, cleaning and parking. Otherwise, the apparent gain may simply reflect leaving part of the job unfinished.
A short work study can use six entries: setup, material preparation, productive transfer, waiting, repositioning and cleanup. Time several representative batches rather than relying on the fastest demonstration. This reveals whether length, layout or another machine is actually limiting the result.
Ownership calculations need real quotations
Use actual purchase, delivery and service quotes. Include the necessary towing connection and any storage changes. For used equipment, include identified repairs before calculating whether the lower asking price is attractive.
As an illustrative break-even calculation, suppose an additional annual ownership cost is $900 and the conveyor saves thirty labour-hours over the year. The cost is $30 per labour-hour saved. If it saves only ten hours, the figure becomes $90. These are invented costs and savings used to show sensitivity, not Canadian market prices.
Convenience may still justify ownership even when the monetary calculation is not decisive. State that preference honestly. There is no need to invent commercial throughput or high annual utilization to explain why an owner values a less repetitive handling routine.
Used-conveyor inspection priorities
Match the serial number to the correct manual, then inspect the structure, trough, chain or belt, drive components, bearings and guards with the equipment safely isolated. Look for damage, wear, missing parts and repairs that need qualified assessment.
Include the positioning system. Angle adjustment, locks, supports, wheels and hitch components affect whether the machine can be used and moved correctly. A conveyor that transports wood but cannot be secured in its approved position is not ready for service.
Demonstrate representative material under the permitted procedure, including shutdown and repositioning. A brief empty run does not show how the complete receiving arrangement behaves. Keep any diagnosis separate from unsupported claims that a particular model commonly fails.
Verify the transport package independently. A hitch and tires do not establish that every vehicle or road movement is appropriate. Use the machine instructions and the requirements for the intended arrangement.
Frequently asked questions
Should I buy the longest conveyor I can store?
Only if its measured working benefit justifies the larger package. Extra length can improve reach and height, but it also changes positioning, storage and movement. Start with the actual receiving geometry.
Can I use the maximum pile height as trailer clearance?
No. Verify the relevant discharge geometry, the receiving edge and where the material lands. The headline figure describes a different measurement.
Does a conveyor make my splitter faster?
It may reduce downstream handling or waiting, but it does not change the splitter’s cylinder performance. Measure the complete batch to see whether that downstream improvement matters.
Can pivoting wheels spread the pile while the machine runs?
Do not assume so. The CT examples require stopping and emptying before changing position. Follow the exact machine’s instructions and include the required pauses in the work plan.
What should decide the final purchase?
A verified fit between inlet, receiving point and operating space, plus a demonstrated improvement in the complete firewood routine. Length is a specification to match to that plan, not a substitute for the plan.
A short worksheet for the demonstration
Bring the yard sketch and a list of the receiving vehicles or containers actually used. Record the inlet height, required discharge position, available approach space and approved storage envelope. Photograph or note the proposed arrangement while the equipment is safely stopped, so the comparison can be reviewed later without relying on memory.
For the material trial, record the normal piece range, how pieces arrive, any planned pauses and the point at which the receiver needs changing or the conveyor needs moving. Ask for the exact machine configuration and serial-range documentation with the quotation. The result should be a repeatable layout and a complete package, not merely a demonstration that wood can travel up a trough.